The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 139, No 9, 1237-1243.
© 2008 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Ludlow, J. B.
Right arrow Articles by White, S. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ludlow, J. B.
Right arrow Articles by White, S. C.
Related Collections
Right arrow Imaging

RESEARCH

JADA Continuing Education

Patient Risk Related to Common Dental Radiographic Examinations

The Impact of 2007 International Commission on Radiological Protection Recommendations Regarding Dose Calculation



John B. Ludlow, DDS, MS, Laura E. Davies-Ludlow, BS and Stuart C. White, DDS, PhD

Background. In 2007, the International Commission on Radiological Protection (ICRP) revised estimates of the radiosensitivity of tissues including those in the maxillofacial region. The authors conducted a study to reassess patients’ risk related to common dental radiographic exposures using the 2007 ICRP recommendations.

Methods. The authors used a tissue-equivalent head phantom to measure dose. They calculated effective doses by using both 1990 and revised 2007 ICRP recommendations. Effective dose is a calculation that takes into consideration the different sensitivities of organs to long-term effects from ionizing radiation. It is the preferred method for comparing doses between different types of exposures.

Results. Effective doses (per the 2007 ICRP) in microsieverts were as follows: full-mouth radiographs (FMX) with photo-stimulable phosphor (PSP) storage or F-speed film with rectangular collimation, 34.9 µSv; four-image posterior bitewings with PSP or F-speed film with rectangular collimation, 5.0 µSv; FMX using PSP or F-speed film with round collimation, 170.7 µSv; FMX with D-speed film and round collimation, 388 µSv; panoramic Orthophos XG (Sirona Group, Bensheim, Germany) with charge-coupled device (CCD), 14.2 µSv; panoramic ProMax (Planmeca, Helsinki, Finland) with CCD, 24.3 µSv; posteroanterior cephalogram with PSP, 5.1 µSv; and lateral cephalogram with PSP, 5.6 µSv. These values are 32 to 422 percent higher than those determined according to the 1990 ICRP guidelines.

Conclusions. Although radiographs are an indispensable diagnostic tool, the increased effective doses of common intraoral and extraoral imaging techniques are high enough to warrant reconsideration of means to reduce patients’ exposure.

Clinical Implications. Clinicians can reduce patients’ dose substantively by using digital receptors or F-speed film instead of D-speed film, rectangular collimation instead of round collimation and radiographic selection criteria.

Key Words: Dental radiography; radiation dosage; risk assessment

Abbreviations: ADA: American Dental Association. • BW: Bitewing. • CCD: Charge-coupled device. • E: Effective dose. • FMX: Full-mouth radiographs. • HT: Equivalent dose. • IRCP: International Commission on Radiological Protection. • MEACR: Mass energy absorption coefficient ratio. • PA: Posteroanterior. • PSP: Photo-stimulable phosphor. • TLD: Thermoluminescent dosimeter. • wT: Tissue-weighting factor.