The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 138, No 12, 1599-1603.
© 2007 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, J. J.
Right arrow Articles by Ritter, A. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, J. J.
Right arrow Articles by Ritter, A. V.
Related Collections
Right arrow Dental Equipment/Instruments

RESEARCH

Using Extracted Teeth for Research

The Effect of Storage Medium and Sterilization on Dentin Bond Strengths



Jason Jonghyuk Lee, DDS, Anthony Nettey-Marbell, DDS, Archie Cook Jr, DDS, Luiz A.F. Pimenta, DDS, MS, PhD, Ralph Leonard, DDS, MPH and André V. Ritter, DDS, MS

Background. The Centers for Disease Control and Prevention has adopted guidelines for infection control of extracted teeth used for research and teaching, requiring that teeth be sterilized before use. The authors conducted a study to test the null hypothesis that the storage medium and sterilization method have no effect on composite-to-dentin bond strengths.

Materials and Methods. The authors collected 170 bovine incisors, cleaned them and placed them randomly into one of six storage media at 37°C for 60 days: distilled water (dH2O), 0.9 percent sodium chloride, 0.5 percent chloramine-T, 5.25 percent sodium hypochlorite (NaClO), 2 percent glutaraldehyde and 10 percent formalin. For sterilization, they autoclaved a subset of 10 specimens from every sample, while they stored another subset of 10 specimens from every sample (except for the 10 percent formalin sample) in 10 percent formalin for 14 days. The authors then embedded the specimens in epoxy and ground flat the facial surface to expose middle-depth dentin, which they polished to 600 grit. They used a dental adhesive to apply composite to the exposed dentin. The authors tested the composite-to-dentin shear bond strength 24 hours after bonding. They analyzed the data using global analysis of variance and, when appropriate, multiple post hoc tests (P = .05).

Results. Storage in NaClO resulted in significantly lower bond strength than that of the other treatment specimens. Sterilization with the autoclave negatively affected the bond strength of specimens stored initially in dH2O or 10 percent formalin, while sterilization with formalin alone had no significant effect on bond strengths.

Conclusions. Storing bovine teeth in 5.25 percent NaClO may negatively affect composite-to-dentin bond strengths. Immersion in 10 percent formalin might be the best option for storage and sterilization of bovine teeth that are to be used in dental bonding studies in vitro.

Key Words: Storage medium; extracted bovine teeth; sterilization of teeth; dentin bonding

Abbreviations: CDC: Centers for Disease Control and Prevention • dH20: Distilled water • NaCl: Sodium chloride • NaClO: Sodium hypochlorite • SBS: Shear bond strength







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright©1995-2007 American Dental Association (ADA).
Reproduction or republication strictly prohibited without prior written permission of ADA.