The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 108, No 2, 175-178.
© 1984 American Dental Association

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaufman, E
Right arrow Articles by Truelove, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaufman, E
Right arrow Articles by Truelove, E.
Journal of the American Dental Association, Vol 108, Issue 2, 175-178
Copyright © 1984 by American Dental Association


Journal Article

Intraligamentary anesthesia: a double-blind comparative study



E Kaufman, L LeResche, E Sommers, SF Dworkin, and EL Truelove

Three local anesthetic agents (Xylocaine 2%, Xylocaine 2% with epinephrine 1:50,000, and Marcaine 0.5 with epinephrine 1:200,000) were injected intraorally using an intraligamentary injection technique. The study used a double-blind design and electrical tooth pulp stimulation to examine the duration of pulpal anesthesia. Patterns of recovery from each drug, subjective discomfort associated with each drug, pain of injection, and pain in comparison with local infiltration were also measured. The extent and duration of adjacent soft tissue anesthesia were recorded. Xylocaine 2% with epinephrine 1:50,000 produced the longest pulpal anesthesia. The decay pattern of this particular drug was less abrupt than that of the two others. No difference in discomfort or pain was found across the various drugs. There was no significant difference in pain at injection when intraligamentary anesthesia was compared with local infiltration. Post-injection pain was slightly lower with local infiltration. The extent of soft tissue anesthesia was significantly related to vasoconstrictor levels in the drugs. The study shows that duration of pulpal and soft tissue anesthesia can be tightly controlled by the operator and tailored specifically to planned dental procedures.


This article has been cited by other articles:


Home page
JDRHome page
R.W. Edwards and T.W. Head
A Clinical Trial of Intraligamentary Anesthesia
Journal of Dental Research, July 1, 1989; 68(7): 1210 - 1213.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright©1995-1984 American Dental Association (ADA).
Reproduction or republication strictly prohibited without prior written permission of ADA.